NMEA 2000 Micro Drop Cables, Male to Female Double Ended with M12 A-Coding 5Pin Connectors by Molded with 22AWG*1Pair + 24AWG*1P + Drain + Braid, Individually Shielded Twisted Pairs, DeviceNet Cable.

■ Overmolding: TPU, black
■ Phosphor bronze female contacts, Brass male contacts, Gold Plated 3μ", machined solid contacts
■ PA66+GF Plastic coupling screw
■ Temperature rated: -40℃ ~ 80℃
■ Characteristic impedance: 120 ohm +/- 10
■ Connector’s mating life: ≥500 times
■ Protection class IP67
NMEA 2000 Mini Cables, Male to Female Double Ended with 7/8" Mini-Change 5Pin Connectors Molded with 15AWG*1Pair + 18AWG*1P + Drain + Braid, Individually Shielded Twisted Pairs, DeviceNet Cable.

■ Overmolding: TPU, black
■ Phosphor bronze female contacts, Brass male contacts, Gold Plated 3μ", machined solid contacts
■ PA66+GF Plastic coupling screw
■ Temperature rated: -40℃ ~ 80℃
■ Characteristic impedance: 120 ohm +/- 10
■ Connector's mating life: ≥500 times
■ Protection class IP67
A Tee is used to tap into the trunk line for adding a drop connection. T-Connectors are used to connect a NMEA 2000 device to the NMEA 2000 backbone; it is an adaptor or splitter between the Trunk line and Drop line. The T-Connector splits wires into 2 separate connectors, allowing installation of two single-channel input or output devices to each port of hardwired distribution box. Connectors are available with parallel circuits, which allow input or output signals to run or trigger devices simultaneously.

● M12 A-Code 5Pin
● Voltage rating:60V
● Current rating:4A
● Anti-vibration
● IP67 protection degree
A Powertap Tee is connected to a network backbone just like any Tee but rather than connecting a device their purpose is to provide "BUS" power. Cableforce Powertap Tee uniquely provides two power inputs permitting doubled power provision for devices.

● M12 A-Code 5Pin
● Voltage rating:60V
● Current rating:4A
● Anti-vibration
● IP67 protection degree
Two termination resistors are required on every NMEA 2000 network, one on each end of the
trunk line. Normally, a male termination is used since male pins tend to point back to the power
source. In cases where the gender is reversed, a female terminator may be required. The inline terminator is used where the network is terminated at a product, for example a GPS or weather station at the top of a mast.

● M12 A-Code 5Pin
● Screw terminal connector for positive connections
● Termination resistors are used to terminate both ends of the trunk line
● Resistance: 120Ω +/-1%,0.6W
● IP67 and Anti-vibration design
Field-attachable connectors allow you to make field connections to bulk cable. The connectors are keyed for error-free connection of field installation.

- M12 A-Code 5Pin or 7/8" Mini Change 5Pin
- Voltage and current rating: 4A/60V, 8A/300V
- Rugged housing material designed to withstand harsh marine environments
- Useful in tight spaces or where sharp corners need to be made
- Waterproof rated to IP67
The NMEA 2000 micro cable includes signal, power and ground for powering equipment drawing less than 1 amp/ device. the cable with double shielded layer design.

● Power twisted pair: 22AWG*1Pair SR-PVC insulation
● Singnal twisted pair: 24AWG*1P fomed PE insulation
● Drain wire: 22AWG without insulation
● Individually Shielded Twisted Pairs
● Characteristic impedance: 120Ω +/- 12